OPTIONAL ACCESSORIES
14-4 SM SX Ser1-A.3 GB
1
All Season Kit Installation Instruction(for ST units only)
Switch off power supply to the unit
Fig.1
Fig.2
Mount the Fan speed controller on the partition
of the compressor compartment in the holes pro-
vided, using four supplied screws .
Note:
In outdoor models OU8, the Fan Speed Control-
ler should be mounted on the partition toward the
outdoor fan motor side.
Fig.2
OU7
OU8
OU10
Fig.3
Unscrew the cap of the provided service valve D
and connect to the T-valve, supplied in the kit.
Use Copper sealing gasked between the flare nut
and it’s connection to service valve D.
Note:
● The “T-valve” supplied in the kit is installed be-
tween valve D and capillary E offering the possi-
bility of an additionall pressure connecting output
for service.
Fig.1
Fig.3
A
C
Additional pressure
output
E
T-valve
D
B
Service valve
cap
gnilaes repooC
teksag
Remove:
– Cover A;
– Power panel handle B;
Side cover C (if it exist).